Search results

Jump to navigation Jump to search
  • DWORD Z size TYPE Values (repeat for x*z times, byte size depends on Type ID)
    2 KB (371 words) - 04:21, 18 March 2020
  • BYTE Min Tract Z (normally between 0x40 and 0x7f) WORD Z Tract Size? (only seen 0x0002, probably indicating the size is 2²)
    2 KB (426 words) - 07:24, 3 March 2024
  • ...style="margin:.5em; margin-top:.1em; border-bottom:0; font-weight:bold;">A–Z Index</h2> |'''-z'''<BR/>'''-Z'''
    2 KB (283 words) - 15:33, 4 August 2019
  • DWORD Z coordinate of anchor building DWORD Min Z coordinate of lot
    2 KB (393 words) - 05:06, 6 July 2021
  • BYTE Min Tract Z Coordinate (normally between 0x40 and 0x7F) BYTE Max Tract Z Coordinate (normally between 0x40 and 0x7F)
    5 KB (763 words) - 12:33, 6 July 2021
  • ...and unfortunately no longer has time to continue working on RTMT. {{member|z}} volunteered to take over the development and maintenance of this project. ...ex.php?topic=5634.0 this thread] at [[SC4D]], that was written by {{member|z}}''</sub>
    2 KB (262 words) - 18:47, 8 August 2019
  • BYTE Min Tract Z Coordinate (normally between 0x40 and 0x7F) BYTE Max Tract Z Coordinate (normally between 0x40 and 0x7F)
    3 KB (461 words) - 18:27, 9 August 2019
  • BYTE×4 (Min Tract X, Min Tract Z, Max Tract X, Max Tract Z) coordinate WORD×2 Tract size (X, Z)
    6 KB (748 words) - 02:14, 19 February 2023
  • Zoom (1 byte), Rotation (1 byte), X position (3 bytes), Z position (3 bytes). *X and Z positions are measured in tiles, from 0,0.
    3 KB (543 words) - 19:54, 8 August 2019
  • {{:Keyboard Shortcuts/row|z|Zone light density Industrial}}
    1 KB (136 words) - 03:52, 20 July 2020
  • BYTE Min Tract Z Coordinate (normally between 0x40 and 0x7F) BYTE Max Tract Z Coordinate (normally between 0x40 and 0x7F)
    6 KB (960 words) - 19:39, 9 August 2019
  • exclusion cells - Sound Exclusion Cell Coordinates. Format : (x,z) (x,z) etc
    3 KB (505 words) - 19:54, 8 August 2019
  • BYTE Min Z Tile BYTE Max Z Tile
    8 KB (1,363 words) - 18:24, 9 August 2019
  • DWORD <<<---Z-Axis Push Minimum DWORD <<<---Z-Axis Push Maximum
    12 KB (1,666 words) - 19:54, 8 August 2019
  • BYTE Min Tract Z Coordinate BYTE Max Tract Z Coordinate
    8 KB (1,305 words) - 19:23, 4 August 2019
  • |{{member|MAS71}}||SC4D's Mazinger-Z||
    2 KB (299 words) - 03:53, 9 August 2019
  • WORD Z tile DWORD Tile Z (63, 127 or 255 for a new city, smaller for built up cities, probably max
    22 KB (3,177 words) - 02:21, 21 December 2024
  • DWORD Z size (65, 129, 257)
    2 KB (322 words) - 05:14, 5 January 2025
  • The path points are presented as a list of coordinates in Z,X,Y format. The first point is the Entry Point position, and the last point The Stop Point is presented as a coordinate in Z,X,Y format. For stop paths, this is just one line as they are stopping poin
    9 KB (1,462 words) - 22:43, 3 August 2019
  • 5 | * | Z Location Position. 0x00000000-0xFFFFFFFF 5 | * | Z Location Position. #/N.NNN
    6 KB (844 words) - 07:18, 14 March 2020

View (previous 20 | next 20) (20 | 50 | 100 | 250 | 500)